This example illustrates how to configure the SPC check function to monitor multiple NVs of a process flow. In the event of a SPC violation the configuration is set to block the taveler from moving forward, to display a Popup message and to send an email to the supervisor. The example configured is a simple three step process with NVs to be monitored on Step 1 and Step 3:

Process Flow (Make Widget)

  • Step 1: 'Number Value Entry' NV to be monitored
  • Step 2: No SPC Check enabled
  • Step 3: 'Number' NV to be monitored

To configure the process flow for SPC Checking we first select our initial step in the flow and the NV to be monitored:

SPC_Check_7

Next open the SPC Tab for the NV, enable the SPC Checker, Block Traveler Move and configure the SPC tests to be performed on the data:

SPC_Check_8-

Repeat the above procedure for the third step in the process flow 'Step 3'. Now we have enabled the SPC Checker to block the traveler from moving and to display a Popup message 'SPC Violation' in the event of any SPC failure. The next feature to configure is to send an email automatically to the supervisor.

SPC_Check_10

Next we must create the trigger and the action before finally adding the trigger and action to the Event 'SPC Event'.

SPC_Check_11

Move the new trigger 'SPC Event Trigger' to the Active state and we can add both our Trigger and Action to the Event. For this example I have already configured a SPC Failure Email Action, for more details on how to create Actions please use the useful links at the bottom of this page.

SPC_Check_12

Now we have fully configured our SPC Event with a trigger and an action we can attach the Event to the Step Definitions that we wish to monitor using the SPC Check function.

SPC_Check_13

Repeat the above procedure for Step 3 and the SPC Check function will monitor the two steps for any SPC violations as defined above.